Oxygen is a violent combustion improver that can easily cause burning and explosion.
Special care should be taken when designing and using tank reciprocating oxygen compressor: Compressed gas parts are strictly prohibited from coming into contact with oil, oil is not contaminated during maintenance, and must be cleaned with solvent before assembly.
Since 1995, we have been developing our liquid oxygen concentrator compressor system. When manufacturing every component that comes into contact with the gas, we follow strict oxygen cleaning guidelines and maintain a detailed cleaning record.
This medical liquid oxygen compressor is suitable for inlet pressure 3-4barg (40-60psig) and discharge pressure 10barg (145psig)
The medium and small PSA air separation oxygen system with a flow rate of 100NM3-500NM3/hour can run continuously for 24 hours.
This liquid medical oxygen compressor features
It adopts 1 or 2-stage compression, stainless steel cylinders, each with safety valve, the inlet is equipped with low intake pressure protection, the exhaust end is equipped with high exhaust pressure protection, and each stage has a temperature sensor. Overpressure, the system will alarm and stop, ensure safe operation, small size, light weight, forklift parking position at the bottom, can be easily moved
All standard medical oxygen compressor for concentrator are CE marked to meet the requirements of the EU market. We can also provide customized oxygen compressors according to customer conditions.
turbo electrochemical oxygen compressor have the following features
According to the medical oxygen compressor for concentrator different working conditions of the customer:
1. Oxygen for VPSA PSA and LOX gas source
2.NO pollution, keep the same purity into the gas
3.RELIABLE and the highest quality, comparable to the American RIX brand.
4. TOP low cost, low maintenance cost and simple operation
5. According to the customer's specific working conditions, the compressor is designed for single machine compression, two-stage compression, three-stage compression and four-stage compression.
6. Low speed, long life, average speed 260-350RPM,
7. Low noise, average noise below 75dB, can work quietly in the medical field
8, continuous continuous heavy-duty operation, can run continuously for 24 hours without stopping
9. Each stage has an interstage safety valve. If the stage is overpressured, the safety valve will take off and release the overpressure gas to ensure the stable operation of the compressor.
10. Each level has a temperature controller. If the temperature between the stages exceeds the standard, the temperature display will sound and light alarm.
11. Obtain CE certification
Model 型号 | Working medium 工作介质 | suction pressure 进气压力(Mpa,Psig) | Discharge pressure 排气压力(Mpa,Psig) | Motor.KW 电机功率 | Flow rate Nm3/hr 流量 | Voltage 电源电压 | Cooling way 冷却方式 | pressure riato |
OW-420/4.5-8 | oxygen | 0.45,60 | 0.8,115 | 30 | 420 | 220V/380V/415V/440V 50/60HZ | Air cooling | 1stage |
1.The above parameters are for reference only, and the technical data is subject to our final technical solution
2.More displacement, higher filling pressure, please consult us
3.Kinly note ,if you have compressor inquiry please tell us follows information when you send inquiry:
*Compressor working medium:
If single gas ,how many purity ? if mixed gas , what’s gas content lit ?
*Suction pressure(gauge pressure): barg
*Exhaust pressure(gauge pressure): barg
*Flow rate per hour for compressor: (Nm3/hr):
Compressor gas suction temperature ?
Compressor working hours per day : hours
Compressor working site altitude : m
Environment temperature ℃:
Has cooling water in the site or not ?
Voltage and frequency for three phase :
Do not has water vapor or H2s in the gas ?
Application for compressor?