cooling way: | |
---|---|
Color: | |
packing box: | |
ETD time: | |
Availability: | |
Quantity: | |
CW-30/2-65
BAILIAN
8414804090
oil free co2 compressor refers to a compressor for pressurizing carbon dioxide gas and achieving transportation. Mainly used,
1. Recycling of dry ice volatilized gas from CO2 plant, recycling of CO2 from factory,
2. Industrial and pharmaceutical extraction processes using the liquid properties of CO2
3. Large-scale carbon dioxide compressor is mainly used in urea synthesis equipment
When co2 oil free recovery compressor extraction designing and using, it should be noted that: (1) the critical temperature of carbon dioxide is high, and it can be liquefied at 31.3 ° C and 7.14 MPa. When used in winter, the interstage cooling temperature should not be too low; (2) when carbon dioxide is below 60 MPa, it is beneficial to gas. (3) Due to the relatively high relative density of carbon dioxide gas, it is not appropriate to use an excessively large average piston speed, otherwise the gas valve resistance is high; (4) carbon dioxide gas contains a small amount of water, which is highly corrosive, so the gas valve, Coolers and buffer tanks are required to be made of stainless steel.
here is oil free extraction co2 compressor technical data
Model | Working medium | suction pressure (Mpa,Psig) | Discharge pressure (Mpa,Psig) | Motor.KW | Flow rate Nm3/hr | Voltage | Cooling way |
CW-30/0.05-20 | CO2 | Atmosphere | 2,287 | 7.5kw | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/3-30 | CO2 | 0.3,43 | 3,430 | 7.5 | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/2-65 | CO2 | 0.2,28 | 6.5,935 | 30 | 11 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/55-80 | CO2 | 5.5,790 | 8,1150 | 1.1 | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-80/0.05-20 | CO2 | Atmosphere | 2,287 | 18.5 | 80 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-105/0.2-25 | CO2 | 0.02,3 | 2.5,360 | 30 | 105 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-100/0.05-20 | CO2 | Atmosphere | 2,287 | 22 | 100 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-110/0.02-18 | CO2 | Atmosphere | 1.8,260 | 30 | 110 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-135/0.05-20 | CO2 | Atmosphere | 2,287 | 30 | 130 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-250/2-25 | CO2 | 0.2,28 | 2.5,360 | 37 | 250 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-300/1-25 | CO2 | 0.1,14 | 2.5,360 | 45 | 300 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-1200/70-150 | CO2 | 7,1000 | 15,2150 | 55 | 1200 | 220V/380V/415V/440V 50/60HZ | water cooling |
1. The above parameters are for reference only, and subject to the final technical quotation
2. More displacement, higher filling pressure, please consult us
oil free co2 compressor refers to a compressor for pressurizing carbon dioxide gas and achieving transportation. Mainly used,
1. Recycling of dry ice volatilized gas from CO2 plant, recycling of CO2 from factory,
2. Industrial and pharmaceutical extraction processes using the liquid properties of CO2
3. Large-scale carbon dioxide compressor is mainly used in urea synthesis equipment
When co2 oil free recovery compressor extraction designing and using, it should be noted that: (1) the critical temperature of carbon dioxide is high, and it can be liquefied at 31.3 ° C and 7.14 MPa. When used in winter, the interstage cooling temperature should not be too low; (2) when carbon dioxide is below 60 MPa, it is beneficial to gas. (3) Due to the relatively high relative density of carbon dioxide gas, it is not appropriate to use an excessively large average piston speed, otherwise the gas valve resistance is high; (4) carbon dioxide gas contains a small amount of water, which is highly corrosive, so the gas valve, Coolers and buffer tanks are required to be made of stainless steel.
here is oil free extraction co2 compressor technical data
Model | Working medium | suction pressure (Mpa,Psig) | Discharge pressure (Mpa,Psig) | Motor.KW | Flow rate Nm3/hr | Voltage | Cooling way |
CW-30/0.05-20 | CO2 | Atmosphere | 2,287 | 7.5kw | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/3-30 | CO2 | 0.3,43 | 3,430 | 7.5 | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/2-65 | CO2 | 0.2,28 | 6.5,935 | 30 | 11 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-30/55-80 | CO2 | 5.5,790 | 8,1150 | 1.1 | 30 | 220V/380V/415V/440V 50/60HZ | air cooling |
CW-80/0.05-20 | CO2 | Atmosphere | 2,287 | 18.5 | 80 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-105/0.2-25 | CO2 | 0.02,3 | 2.5,360 | 30 | 105 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-100/0.05-20 | CO2 | Atmosphere | 2,287 | 22 | 100 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-110/0.02-18 | CO2 | Atmosphere | 1.8,260 | 30 | 110 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-135/0.05-20 | CO2 | Atmosphere | 2,287 | 30 | 130 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-250/2-25 | CO2 | 0.2,28 | 2.5,360 | 37 | 250 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-300/1-25 | CO2 | 0.1,14 | 2.5,360 | 45 | 300 | 220V/380V/415V/440V 50/60HZ | water cooling |
CW-1200/70-150 | CO2 | 7,1000 | 15,2150 | 55 | 1200 | 220V/380V/415V/440V 50/60HZ | water cooling |
1. The above parameters are for reference only, and subject to the final technical quotation
2. More displacement, higher filling pressure, please consult us